slider
slider
slider
slider
slider

Brands Safe-T-Fill®

Safe-T-Fill® Capillary Blood Collection Tube Clot Activator / Separator Gel Additive 200 µL Attach ... Read more

Product # : 329981 Class : MCKSN Distributor : RELIANCE INC Category : Tubes Availability : Please contact customer service to check availability.
Non-Stock Item Information : Any reason may apply
  • This item ships directly from the manufacturer. Additional shipping charges may apply.
  • As a special order from the supplier, the approximate delivery time is 2-4 weeks.
  • For equipment such as beds, lifts, etc., a freight code is required. Please reach out to us to get the code.

$0.00

Volume
Product Notices : This product may be non-returnable and/or require additional restocking fee.
Product Varient
Volume
Dimensions

Product Specifications

Product No. # 329981
Manufacturer # 077421
Brand Safe-T-Fill®
Manufacturer ASP Global LLC
Country of Origin Germany
Additive Clot Activator / Separator Gel Additive
Application Capillary Blood Collection Tube
Material Plastic Tube
Sterility NonSterile
Volume 200 µL
Sterility NonSterile
Dimensions 10.8 X 46.6 mm
Shipping Width 6.8
Shipping Height 1.5
Shipping Depth 6.4
Dimension UOM IC
Shipping Weight 0.23
Weight UOM LB
Closure Type Attached Cap
Dimensions 10.8 X 46.6 mm
Material Plastic Tube
QTY_Per_Sell 50
Sterility NonSterile
Type Serum Tube
Volume 200 µL
Simply_Medical_Category Tubes
Coating Kaolin Coated Tube
Color Code Red
RCF_Rating 4,000xG
Supply_Manager_Category Tubes
Supply_Manager_Hierarchy Clinical Laboratory>Laboratory Glassware and Plasticware>Tubes>Capillary Blood Collection Tube
Legend_Code No
Stock_Status NonStock
Velocity Slow Selling
GTIN 10643351000182
Country of Origin Germany
Other Popular Suggestions
Features
  • Pre-assembled with a capillary straw, attached pierceable cap, and a microtube: 100% plastic tubes collect microliter volume capillary blood samples from finger and heel sticks
  • Capillary straw and microtube are coated with a clotting activator to facilitate clotting.
  • Attached cap is color-coded red to designate the type of additive that is in both the capillary tube and the microtube.
  • Lot number, expiration date and fill lines are printed directly on the microtube.
  • A complete end-to-end fill of the capillary straw accurately measures the stated fill volume.
  • For light-sensitive serum determinations in chemistry
  • Gel separator serves as a barrier between blood and serum after centrifugation.
  • Amber microtube ensures light-sensitive sample integrity providing protection for testing (e.g. bilirubin).
  • Kaolin coated serum tube